TH-G0208M2-R Layer2 Yoyendetsedwa ndi Efaneti Switch 2xGigabit SFP, 8×10/100/1000Base-T

Nambala Yachitsanzo:Chithunzi cha TH-G0208M2-R

Mtundu:Todahika

  • Kuthandizira padoko auto flip (Auto MDI/MDIX)
  • Chizindikiro cha gulu chomwe chimayang'anira momwe zinthu ziliri ndikuthandizira kulephera

Tsatanetsatane wa Zamalonda

Mawonekedwe

Kuyitanitsa Zambiri

Zofotokozera

Dimension

Zolemba Zamalonda

Mafotokozedwe Akatundu

Gigabit Layer 2 Managed Switch imathandizira Madoko a 8xGigabit Efaneti + 2xGigabit SFP Ports, amangosintha kuti agwirizane ndi duplex yonse kapena theka la duplex.Kudziphunzitsa nokha adilesi ya MAC kumatsimikizira kufalitsa kwa data popanda zolakwika, ndipo sitolo ndi njira yopita patsogolo imalepheretsa mapaketi owonongeka kuti asasefukire pamaneti.Ntchito yoyendetsa kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe ka kayendetsedwe kake

Zosintha zingapo izi zimapereka ntchito zapamwamba zowongolera maukonde: ma ring ring network, VLAN, cluster, QoS, kuwongolera liwiro, chithunzi cha doko, alamu yolakwika ndi kukweza kwa firmware pa intaneti, zomwe zimagwiritsidwa ntchito kwambiri pazopezeka za Ethernet monga mabizinesi ang'onoang'ono ndi apakatikati, malo odyera pa intaneti. , mahotela, masukulu, ndi zina.

Mtengo wa TH-8G0024M2P

  • Zam'mbuyo:
  • Ena:

  • ● Thandizani IEEE802.3/ IEEE802.3u/ IEEE802.3ab/IEEE802.3z, sitolo-ndi-mtsogolo

    ● Flow control mode: full-duplex itengera IEEE 802.3x muyezo, theka-duplex itengera Back pressure standard

    Kuthandizira padoko auto flip (Auto MDI/MDIX)

    ● Chizindikiro cha gulu chimayang'anira momwe zinthu zilili ndikuthandizira kulephera

    ● Kuthandizira kutsimikizika kwa doko kwa 802.1x, kuthandizira kutsimikizika kwa AAA, kuthandizira kutsimikizika kwa TACACS+

    ● Thandizani WEB, TELNET, CLI, SSH, SNMP, RMON management

    ● Surge Protection: General 4KV, Differential 2KV, ESD 8KV mpweya, 6KV kukhudzana

    GAWO NO. DESCRIPTION
    Chithunzi cha TH-G0208M2-R Layer2 Yoyendetsedwa ndi Efaneti Switch 2xGigabit SFP, 8×10/100/1000Base-T

    I/O Interface

    Kulowetsa Mphamvu

    AC 100-240V, 50/60Hz

    Fixed Port

    8 * 10/100/1000Mbps Efaneti Port

    2 * 1000Mbps SFP Port

    1 * Console Port

    Kachitidwe

    Bandwidth

    20Gbps (osatsekereza)

    Packet Forwarding rate

    14.88Mp

    Paketi Buffer

    4M

    Kukhoza kukumbukira

    128 MB

    Kuthekera kwa Flash

    16 MB

    Adilesi ya MAC

    8K

    Zithunzi za VLAN

    4096

    Jumbo Frame

    9.6KB

    Transfer Mode

    Sungani ndi kutsogolo

    Mtengo wa MTBF

    100000 ora

    Standard

    Network protocol

    IEEE802.3: 10Base-T

    IEEE802.3u: 100Base-TX

    IEEE802.3ab: 1000Base-TX

    IEEE802.3z :1000Base-FX

    IEEE 802.3x: Kuwongolera koyenda

    IEEE 802.1ab: LLDP/LLDP-MED (Link Layer Discovery Protocol)

    IEEE 802.1p: LAN Layer QoS/CoS Protocol Traffic Preoritization (Multicast kusefa ntchito)

    IEEE 802.1q: Ntchito ya VLAN Bridge

    IEEE 802.1x: Kuwongolera Kwamakasitomala/Seva ndi Kutsimikizira Protocol

    IEEE 802.3ad: Njira yokhazikika yochitira ulalo wophatikiza

    IEEE 802.1d: STP

    IEEE 802.1s: MSTP

    IEEE 802.1w: RSTP

    Industry Standard

    EMI: FCC Gawo 15 CISPR (EN55032) kalasi A

    EMS: EN61000-4-2 (ESD)

    EN61000-4-5 (ochita opaleshoni)

    Network Medium

    10Base-T: Cat3/4/5 kapena pamwamba pa UTP(≤100m)

    100Base-TX: Cat5 kapena pamwamba pa UTP(≤100m)

    1000Base-TX: Cat5 kapena pamwamba pa UTP (≤100m)

    Mawonekedwe a Optical

    Mipikisano mode: 850/1310nm (0-2KM)

    Njira imodzi: 1310/1550/1490nm (0-120KM)

    Zikalata

    Setifiketi Yachitetezo

    CE, FCC, RoHS

    Chilengedwe

    Malo Ogwirira Ntchito

    Ntchito Kutentha: -10 ~ 50 ° C

    Kusungirako Kutentha: -40 ~ 70°C

    Chinyezi chogwira ntchito: 10% ~ 90%, chosasunthika

    Kutentha kwa yosungirako: 5% ~ 90%, osasunthika

    Chizindikiro

    Zizindikiro za LED

    PWR, SYS, Link, ACT

    Zimango

    Kukula Kwakapangidwe

    Kukula kwa malonda: 268 * 181 * 44mm

    Phukusi Kukula: 312 * 262 * 84mm

    Net Kulemera kwake: 1.01KG

    Kulemera Kwambiri: 1.54KG

    Packing Info

    Miyeso: 540 * 435 * 332mm

    Kupaka Kuchuluka: 10PCS

    Kulemera kwake: 16.4KG

    Layer 2 Software Function

    Port Management

    Yambitsani/Letsani Port

    Kuthamanga, Duplex, MTU Setting

    Kuwongolera-kuyenda

    Chidziwitso cha Port

    Port Mirroring

    Imathandiza onse mbali-njira doko mirroring

    Port Speed ​​​​Limit

    Imathandizira kasamalidwe ka ma port-based input / output bandwidth

    Port Isolation

    Kuthandizira kudzipatula kwa doko la downlink, ndipo mutha kulumikizana ndi doko la uplink

    Kuletsa Mkuntho

    Imathandizira unicast osadziwika, ma multicast, ma multicast osadziwika,

    kufalitsa mtundu wa storm kuponderezedwa

    Kuponderezedwa kwa mkuntho kutengera kuwongolera kwa bandwidth ndi kusefa kwa mkuntho

    Link Aggregation

    Thandizani static manual aggregation

    Thandizani LACP dynamic aggregation

    Zithunzi za VLAN

    Kufikira

    Thunthu

    Zophatikiza

    Doko lothandizira, protocol, magawo a VLAN opangidwa ndi MAC

    Thandizani kulembetsa kwa GVRP kwamphamvu kwa VLAN

    Mawu VLAN

    MAC

    Thandizani static kuwonjezera, kufufutidwa

    Malire ophunzirira adilesi ya MAC

    Thandizani kusintha kwa nthawi yokalamba

    Mtengo wodutsa

    Thandizani STP yotambasula mtengo protocol

    Imathandizira RSTP Rapid Spanning Tree Protocol

    Imathandizira Protocol ya MSTP Rapid Spanning Tree

    Multicast

    Thandizani static kuwonjezera, kufufutidwa

    Kusintha kwa IGMP

    Thandizani MLD-Snooping

    Thandizani v1/2/3 yowoneka bwino ya multicast

    DDM

    Thandizani SFP/SFP+DDM

    Mtengo wa ACL

    Kutengera gwero la MAC, kopita MAC, mtundu wa protocol, IP source, IP yopita, doko la L4

    Qos

    Kutengera 802.1p (COS) gulu

    Kutengera gulu la DSCP

    Kugawika kutengera IP yochokera, IP komwe mukupita, ndi nambala yadoko

    Thandizani SP, WRR kukonza njira

    Thandizo loyenda malire malire CAR

    LLDP

    Thandizani LLDP link discovery protocol

    Zokonda za ogwiritsa

    Onjezani / chotsani ogwiritsa ntchito

    chipika

    Kulowa kwa ogwiritsa ntchito, ntchito, mawonekedwe, zochitika

    Anti-attack

    Chitetezo cha DOS

    Thandizani chitetezo cha CPU ndikuchepetsa kuchuluka kwa kutumiza mapaketi a CPU

    Kumanga kwa ARP (IP, MAC, PORT yomanga)

    Chitsimikizo

    Thandizani 802.1x kutsimikizika kwa doko

    Thandizani AAA certification

    Network diagnosis

    Thandizani ping, telnet, trace

    System Management

    Kukhazikitsanso chipangizo, sungani masinthidwe / kubwezeretsanso, kasamalidwe kokweza, kuyika nthawi, ndi zina.

    CLI

    Thandizani serial port command line management

    SSH

    Thandizani SSHv1/2 kasamalidwe kakutaliTELNET

    Thandizani telnet kasamalidwe kakutali

    WEB

    Thandizo la Layer 2, Layer 2 ndi Layer 3 monitor

    LLDP

    Thandizani LLDP link discovery protocol

    Zokonda za ogwiritsa

    Onjezani / chotsani ogwiritsa ntchito

    chipika

    Kulowa kwa ogwiritsa ntchito, ntchito, mawonekedwe, zochitika

    Anti-attack

    Chitetezo cha DOS

    Thandizani chitetezo cha CPU ndikuchepetsa kuchuluka kwa kutumiza mapaketi a CPU

    Kumanga kwa ARP (IP, MAC, PORT yomanga)

    Chitsimikizo

    Thandizani 802.1x kutsimikizika kwa doko

    Thandizani AAA certification

    Network diagnosis

    Thandizani ping, telnet, trace

    System Management

    Kukhazikitsanso chipangizo, sungani masinthidwe / kubwezeretsanso, kasamalidwe kokweza, kuyika nthawi, ndi zina.

    CLI

    Thandizani serial port command line management

    SSH

    Thandizani SSHv1/2 kasamalidwe kakutali

    TELNET

    Thandizani telnet kasamalidwe kakutali

    WEB

    Thandizo la Layer 2, Layer 2 ndi Layer 3 monitor

    Chithunzi cha SNMP

    SNMP V1/V2/V3

    Msampha wothandizira: ColdStart, WarmStart, LinkDown, LinkUp

    Mtengo RMON

    Thandizani RMON v1

    Ntchito zina

    Thandizani DHCP Snooping, Option82

    Thandizani kuzindikira kwamphamvu kwa ARP

    Thandizani TACCS + certification

    Thandizani DNS certification

    Thandizani zoikamo zachitetezo cha doko

    Thandizani MVR protoco

    Dimension

    Lembani uthenga wanu apa ndikutumiza kwa ife